When you use the server tool "Stop Server Service" it appears that output buffers are not always flushed to open log files. Is this normal?


Back to top
 Profile  
 
 Post subject:
PostPosted: Thu Jul 28, 2005 10:43 am 
Offline
Site Admin

Joined: Wed Dec 31, 1969 5:00 pm
Posts: 329
Location: Vancouver, BC
When the TeleFlow Server service is stopped, it should finish any pending writes to its log files. You should see the word "SHUTDOWN" near the end of each log, followed by messages related to TeleFlow cleaning up. The very last line should read "All memory released. Exiting...". If you see this message, you have the whole log. If you see the "SHUTDOWN" message, you have all of the log that pertains to your application. <br> <br>Are all of the log files you are referring to TeleFlow Server created logs (ie: the ones corresponding to each line in you .TAL file), or do you have custom log files you are writing to with the Write Text step?


Back to top
 Profile WWW 
 
 Post subject:
PostPosted: Thu Jul 28, 2005 12:53 pm 
Offline

Joined: Mon Mar 15, 2004 3:55 pm
Posts: 35
Location: USA
Yes, they are custom logs with the Write Text step.


Back to top
 Profile  
 
 Post subject:
PostPosted: Mon Aug 01, 2005 1:22 pm 
Offline
Site Admin

Joined: Wed Dec 31, 1969 5:00 pm
Posts: 329
Location: Vancouver, BC
I conducted a test here, and determined that TeleFlow Server does indeed flush its output buffers, on a successful shutdown, including application output via Write Text steps. <br> <br>I wrote a simple loop, which counts its iterations, writes this number to the standard TeleFlow log, and also to a text file with the Write Text step. After a few hundred executions, I stopped the TeleFlow Server service, and both the log and the text file contained data up to the same iteration. <br> <br>My test was conduction on Windows 2000 SP 4 with TeleFlow Server version 2005.0519, the same version that is currently distributed via our website. <br> <br>This could be an O/S related issue, or it could be that TeleFlow Server did not shutdown correctly. It is possible that TFServer errored on exit, and did not get to complete its cleanup code. We are working on some stability issues with respect to the shutdown functionality.


Back to top
 Profile WWW 
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 4 posts ] 

Board index : TeleFlow Forums : General


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
cron
Style by Midnight Phoenix & N.Design Studio
Powered by phpBB © 2000, 2002, 2005, 2007 phpBB Group.